Product Description:
1.Compatible with most common low-voltage batteries (lead-acid & lithium)
2.Max charging/discharging current up to 120A
3.The typical switch time between on-grid mode andback-up mode is 10ms
4.Remote upgrade and configuration; safety-relatedfunctions integrated; easy for cooperating with BMS
5.IP65 protection to ensure the inverter can work undervarious environmental conditions
6.Easily installed in the residential site
Technical Parameters:
| | | | | | | | Battery Type | Li-ion / Lead-acid | Li-ion / Lead-acid | Li-ion / Lead-acid | Li-ion / Lead-acid | Li-ion / Lead-acid | Li-ion / Lead-acid | Nominal Battery Voltage (V) | | | | | | | Battery Voltage Range (V) | | | | | | | Max. Charge/Discharge Current (A) | | | | | | | Max. Charge/Discharge Power (W) | 3000/3000 | 4600/4600 | 5000/5000 | 6000/6000 | 10000/8000 | 10000/10000 | | Max. Array Input Power (W) | 6300 | 9000 | 9000 | 9000 | 12000 | 15000 | Max. DC Input Voltage (V) | 550 | 550 | 550 | 550 | 600 | 600 | Nominal DC Input Voltage (V) | 360 | 360 | 360 | 360 | 360 | 360 | Start-up Voltage (V) | 90 | 90 | 90 | 90 | 90 | 90 | MPPT Voltage Range (V) | 70~540 | 70~540 | 70~540 | 70~540 | 70~540 | 70~540 | Max Input Current per MPPT (A) | 15/15 | 15/15 | 15/15 | 15/15 | 30/22/22 | 30/22/22 | Max Short-circuit Current per MPPT (A) | 20/20 | 20/20 | 20/20 | 20/20 | 40/30/30 | 40/30/30 | No. of MPPT | 2 | 2 | 2 | 2 | 3 | 3 | No. of Strings per MPPT | 1 | 1 | 1 | 1 | 2 | 2 | | Nominal Input Apparent Power (VA) | 3600 | 4600 | 5000 | 6000 | 8000 | 10000 | Max. Input Apparent Power (VA) | 6300 | 9000 | 9000 | 9000 | 12000 | 15000 | Max. Input Current (A) | 29 | 41 | 41 | 41 | 40 | 50 | | Nominal Ouput Active Power (W) | 3600 | 4600 | 5000 | 6000 | 8000 | 10000 | Nominal Output Apparent Power (VA) | 3600 | 4600 | 5000 | 6000 | 8000 | 10000 | Max. Output Apparent Power (VA) | 3960 | 5060 | 5500 | 6600 | 8800 | 11000 | Nominal Output Voltage (V) | 220/230/240 | 220/230/240 | 220/230/240 | 220/230/240 | 220/230/240 | 220/230/240 | Output Voltage Range (V) | 150-300(Adjustable) | - | Nominal Output Frequency (Hz) | 50/60 | Output Frequency Range (Hz) | 45-65(Ajustable) | Max. Output Current (A) | 16 | 22 | 25 | 27.2 | 40 | 50 | Power Factor | ~1 (Adjustable from 0.8 leading to 0.8 lagging) | THDi | <3% | <3% | <3% | <3% | <3% | <3% | | Nominal Output Apparent Power (VA) | 3600 | 4600 | 5000 | 6000 | 8000 | 10000 | Max. Output Apparent Power (VA) | 3960 | 5060 | 5500 | 6600 | 8800 | 11000 | Nominal Output Voltage (V) | 230 | 230 | 230 | 230 | 230 | 230 | Nominal Output Frequency (Hz) | 50/60 | 50/60 | 50/60 | 50/60 | 50/60 | 50/60 | Max. Output Current (A) | 18 | 23 | 25 | 30 | 34.8 | 43.5 | Transfer Time (ms) | 10(typ) / 20(max) | 10(typ) / 20(max) | 10(typ) / 20(max) | 10(typ) / 20(max) | 10(typ) / 20(max) | 10(typ) / 20(max) | THDv @ Linear load | <3% @100% R Load | <3% @ 100% R Load | | Max. Efficiency | 97.30% | 97.30% | 97.30% | 97.30% | 98% | 98% | Battery Discharge to AC Efficiency | 94.30% | 94.30% | 94.30% | 94.30% | 95% | 95% | | PV Reversed Polarity Protection | Yes | Yes | Residual Current Monitor | Yes | Yes | PV Over Voltage Protection | Yes | Yes | PV Over Current Protection | Yes | Yes | Anti-islanding Protection | Yes | Yes | DC Surge Protection | Type III | Type II | AC Surge Protection | Type III | Type II | Insulation Resistor Detector | Yes | Yes | Output Over Current Protection | Yes | Yes | Output Short Circuit Protection | Yes | Yes | Output Over Voltage Protection | Yes | Yes | Generator | - | Yes | AFCI | - | Optional | Remote Shutdown | - | Optional | Rapid Shutdown | - | - | | Operating Temperature Range (°C) | -25℃~60℃ | -25℃~60℃ (>45℃ derating) | Relative Humidity | 0~100% | 0~100% | Max. Operating Altitude (m) | 4000 | 4000 | Cooling Method | Natural Cooling | Fan Cooling | User Interface | APP+LED | LED+APP | Communication | RS485/CAN (for BMS), RS485, USB, DRM/RS485 (for Meter), Optional: WiFi/GPRS/LAN | RS485/CAN (for BMS), RS485, USB, DRM/RS485 (for Meter), Optional: WiFi/GPRS/LAN | Weight (kg) | 20 | 25 | 25 | 25 | 37 | 37 | Dimension (W × H × D mm) | 515*485*175 | 420*800*240 | Topology | Transformerless | Transformerless | Ingress Protection Rating | IP65 | IP65 | Mounting Method | Wall Bracket | Wall Bracket | |





Applications:
Multi-source integration:
Combine solar energy, storage batteries and grid power to achieve flexible energy management and optimize energy efficiency.
Smart Energy Management:
Intelligent management to prioritize energy sources based on real-time conditions and user preferences to maximize savings and efficiency.
Backup power supply:
Provide reliable backup power in the event of a grid failure, ensuring continuous operation of critical loads.
Support grid stability:
Support grid stability by managing energy flows to reduce stress on the grid during peak loads.
User-friendly monitoring:
Equipped with a monitoring system, users can track energy production, consumption and battery status in real time through a mobile app or web interface.
Scalability:
The design is flexible and scalable according to demand, suitable for a variety of applications from home to business.
Environmental Protection:
Promote the use of renewable energy to help reduce carbon emissions and dependence on fossil fuels.
The Off Grid Hybrid Solar Inverter comes with a communication interface, RS232, which allows users to connect it to a computer and monitor and control its performance. This feature makes it easy to keep track of the power output and to troubleshoot any issues that may arise.
The Hybrid Solar Inverter is suitable for a wide range of applications. It can be used in homes, offices, and other buildings that require a reliable power supply. The Off Grid Hybrid Solar Inverter is also suitable for use in remote areas where there is no access to the power grid. It can be used to power lighting, appliances, and other electrical devices.